INSTALLATION GUIDE FOR
VÄNEE 90H* AND VÄNEE 190H
BRONZE MODELS
RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
03451 rev. 04
®
VB0110
*This product earned the ENERGY STAR
®
by
meeting strict energy efficiency guidelines set
by Natural Resources Canada and the US EPA.
It meets ENERGY STAR requirements only
when used in Canada.
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - BRONZE MODELS

INSTALLATION GUIDE FOR VÄNEE 90H* AND VÄNEE 190HBRONZE MODELSRESIDENTIAL USE ONLYREAD AND SAVE THESE INSTRUCTIONS03451 rev. 04®VB0110*This product ea

Página 2 - LIMITATION

4. CONTROLS4.1 INTEGRATED CONTROLAll units are equipped with an integrated control, located in front of the electrical compartment. Use the push butto

Página 3 - TABLE OF CONTENTS

4. CONTROLS (CONT’D)For more convenience, this unit can also be controlled using an optional main wall control. NOTES: 1. The integrated control must

Página 4 - 2. TYPICAL INSTALLATIONS

4. CONTROLS (CONT’D)4.2.3 ELECTRICAL CONNECTION TO OPTIONAL AUXILIARY WALL CONTROLSNOTE: If an optional auxiliary wall control is activated and then,

Página 5 - 3. INSTALLATION

6. WIRING DIAGRAMWARNINGRisk of electric shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source.!Fie

Página 6 - 3. INSTALLATION (CONT’D)

7.1 WHAT YOU NEED TO BALANCE THE UNIT• A magnehelic gauge capable of measuring 0 to 0.5 inch of water (0 to 125 Pa) and 2 plastic tubes.• The balancin

Página 7

8. SERVICE PARTSITEM DESCRIPTION QUANTITY VÄNEE 90H VÄNEE 190H1MOTORIZED DAMPER ASSEMBLY (INCLUDING 18) 1 17235 172352DOUBLE COLLAR PORT 2 02257 02257

Página 8 - Fresh air

9. TROUBLESHOOTINGIf the integrated control LED of the unit is flashing, this means the unit sensors detected a problem. See the list below to know wh

Página 9

ABOUT THIS MANUALBecause of the large amount of models covered by this publication, the illustrations are typical ones. Some details of your unit may

Página 10 - Section 9 Troubleshooting

1. TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 11 - REAR VIEW

2.3 SIMPLIFIED INSTALLATION (CONNECTION TO A FORCED AIR SYSTEM)2. TYPICAL INSTALLATIONSUse the following illustrations as guidelines to help you decid

Página 12 - TERMINAL

- 5 -3. INSTALLATION3.1 INSPECT THE CONTENT OF THE BOX• Inspect the exterior of the unit for shipping damage. Ensure that there is no damage to the do

Página 13 - LOGIC DIAGRAM

3. INSTALLATION (CONT’D)3.4 CALCULATING DUCT SIZE (CONT’D)NOTE: Examples 3.4.1 and 3.4.2 use imperial units. The same calculation applies to metric un

Página 14 - 7. BALANCING THE UNIT

3.5 INSTALLING THE DUCTWORK AND REGISTERS (CONT’D)3.5.2 CENTRAL DRAW POINT SYSTEM (AS ILLUSTRATED IN SECTION 2.2)Stale air exhaust ductworkSame as fo

Página 15 - 8. SERVICE PARTS

3.5 INSTALLING THE DUCTWORK AND REGISTERS (CONT’D)3.5.3 SIMPLIFIED INSTALLATION (AS ILLUSTRATED IN SECTION 2.3) (CONT’D)Fresh air distribution• Same

Página 16 - 9. TROUBLESHOOTING

3.7 INSTALLING 2 EXTERIOR HOODSChoose an appropriate location to install the exteriorhoods:• There must be a minimum distance of 6 feet (1.8 m) betwee